Air Outlet Position |
|
Box | Height Box | Length
Box | Width |
Positive <numeric value>
- Sets dimensions of sides of radiator box.
|
Connection | Side |
- Sets inlet and outlet connections to either Left or Right side of unit.
|
Convector | Type |
Single
- Sets type of convector Single to Sill Single and Trench Single convectors.
-
1-Twins
-
2-TwinTube
-
3-Stacked
- Sets one of the types of convector to Sill Twin and Trench Twin convectors.
|
Depth |
Positive <numeric value>
- Sets depth dimension of convector body.
|
Connection 1 | Length (L1) Connection 2 | Length (L2)
Connection 3 | Length (L3) Connection 4 | Length (L4)
|
Positive <numeric value>
|
Connection | End Type |
fl -<numeric value>
- Sets and sizes end with a flange connection.
m -<numeric value>
- Sets and sizes end with a male connection.
fe -<numeric value>
- Sets and sizes end with a female connection.
Separate End Type entries for each End Spec with a semi colon. Example: fl-2;fe-.13 creates a flange at End1 with size 2, and a female connection at End2 with an overall reduction of component's dimensions of .13
|
Flow | Connection Side |
- Sets either of sides on radiator box for flow connection.
|
Flow | Length |
Positive <numeric value>
- Sets the straight length of Flow connection.
|
Flow Location |
-
1-Panel 1
-
2-Panel 2
-
3-Panel 3
|
Flow | Outer Diameter |
Positive <numeric value>
- Sets outer diameter of flow connection. Keeps Return diameter same.
|
Flow Top Offset |
Positive <numeric value>
- Sets the offset distance between the flow connection and the top of the unit.
|
Flow Valve Type |
-
1-Thermostatic
-
2-Non Thermostatic
- Sets type of flow valve to either one.
|
Inlet | Length |
Positive <numeric value>
- Sets the straight length of Inlet at End1.
|
Length |
Positive <numeric value>
- Sets length dimension of convector body.
|
Mounting Height Mounting Length
Mounting Width |
Positive <numeric value>
- Sets dimensions of sides of mounting unit on radiator panel.
|
Convector | No. of Bars |
<integer>
- Sets number of bars to outlet panel of equipment.
|
No. of Grille Bars |
<integer>
- Sets number of grille bars on grille surface on the device.
|
Number Of Sections |
<integer>
- Sets number of sections in radiator column.
|
Outlet | Length |
Positive <numeric value>
- Sets the straight length of Outlet at End2.
|
Panel Type |
-
1-Single
-
2-Double
-
3-Tripple
|
Radiator Type |
- Sets type of radiator to either one.
|
Return | Connection Side |
- Sets either of sides on radiator box for return connection.
|
Return | Length |
Positive <numeric value>
- Sets the straight length of Return connection.
|
Return Location |
-
1-Panel 1
-
2-Panel 2
-
3-Panel 3
|
Return | Outer Diameter |
Positive <numeric value>
- Sets outer diameter of return connection. Follows Flow diameter.
|
Return Top Offset |
Positive <numeric value>
- Sets the offset distance between the return connection and the top of the unit.
|
Return Valve Type |
-
1-Thermostatic
-
2-Non Thermostatic
- Sets type of return valve to either one.
|
Width |
Positive <numeric value>
- Sets width dimension of convector body.
|